The following issues were resolved in Switch Engine 33.1.1. Version 33.1.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, and 32.7.x.
| Defect Number | Description |
|---|---|
| General | |
| CFD-9644 | show port utilization occasionally displays random values for BPE ports. |
| CFD-9731 | show switch management output is slow and sometimes results in the SNMP timeout. |
| CFD-10220 | The following error log appears in a switch
randomly: <Warn:HAL.FDB.MacVlanAddFail> MAC-based VLAN entry 00:50:B6:BB:D2:17 vlan 100 addition to port 17 failed, Table full |
| CFD-10797 | ARP proxy is not working when ARP entry is present on proxy configured switch. |
| CFD-10916 | Configuration wrongly displays all events are deleted in the default filter when a particular event is excluded. |
| CFD-10987 | "SSL" related commands issued by user accounts are executed properly, but it should be restricted for non-admin accounts. |
| CFD-11196 | Unable to enforce Policy profile from ExtremeCloud IQ Site Engine, when the profile has cos options enabled. |
| CFD-11258 | Port ID is incorrectly displayed when we poll the dot1d port table. |
| CFD-11267 | When DHCP-Snooping is configured only on a PVLAN edge-port, DHCP bindings are not populated properly. |
| CFD-11275 | Scheduled restart is not working as scheduled when the SNTP-client updates the switch time dynamically. |
| CFD-11349 | Process VLAN crashes with signal 6 leading to a switch restart. |
| CFD-11367 | Memory leak occurs in SNMPD process due to failed requests. |
| CFD-11371 | ELRP wrongly detects a loop when both the tenant VLAN and non-tenant VLAN are present in the ISC port. |
| CFD-11404 | Unable to initiate SSH or telnet access to neighboring switches when port isolation is turned on in the connected port. |
| CFD-11518 | Operating system returns different PVID values when dynamic authentication is done on the port while polling for dot1qPvid OID. |
| CFD-11559 | Configuration or the dos-protect detail output does not reflect when the management port is configured as a trusted-port. |
| CFD-11659 | In certain platforms, including X435, X465, and 4120, L3 routed packets with dot1q header having CFI/DEI bit set to 1 are processed in the CPU. |
| CFD-11815 | The ELRP process crashes when ELRP with Hardware Assist is enabled and is run on a VLAN that has more than 128 ports. |
| CFD-11913 | Option to synchronize the files created in the primary slot to the backup is included in the synchronize command. |
| 5320 Series Switches | |
| CFD-11429 | Policy disabled after a restart in 5320 series. |
| 5520 Series Switches | |
| CFD-11278 | 10070H optic port on 5520-48SE does not come up after reinserting and when the port speed is configured as 100Mbps. |
| 7520 Series | |
| CFD-11737 | 25G link does not come up after turning off/on Auto-neg settings in 7520. |