Resolved Issues in Switch Engine 33.1.1

The following issues were resolved in Switch Engine 33.1.1. Version 33.1.1 includes all fixes up to and including versions 31.6, 31.7, 32.1, 32.2, 32.3, 32.4, 32.5, 32.6.x, and 32.7.x.

Table 1. Resolved Issues, Platform-Specific, and Feature Change Requests (CRs) in 33.1.1
Defect Number Description
General
CFD-9644 show port utilization occasionally displays random values for BPE ports.
CFD-9731 show switch management output is slow and sometimes results in the SNMP timeout.
CFD-10220 The following error log appears in a switch randomly:

<Warn:HAL.FDB.MacVlanAddFail> MAC-based VLAN entry 00:50:B6:BB:D2:17 vlan 100 addition to port 17 failed, Table full

CFD-10797 ARP proxy is not working when ARP entry is present on proxy configured switch.
CFD-10916 Configuration wrongly displays all events are deleted in the default filter when a particular event is excluded.
CFD-10987 "SSL" related commands issued by user accounts are executed properly, but it should be restricted for non-admin accounts.
CFD-11196 Unable to enforce Policy profile from ExtremeCloud IQ Site Engine, when the profile has cos options enabled.
CFD-11258 Port ID is incorrectly displayed when we poll the dot1d port table.
CFD-11267 When DHCP-Snooping is configured only on a PVLAN edge-port, DHCP bindings are not populated properly.
CFD-11275 Scheduled restart is not working as scheduled when the SNTP-client updates the switch time dynamically.
CFD-11349 Process VLAN crashes with signal 6 leading to a switch restart.
CFD-11367 Memory leak occurs in SNMPD process due to failed requests.
CFD-11371 ELRP wrongly detects a loop when both the tenant VLAN and non-tenant VLAN are present in the ISC port.
CFD-11404 Unable to initiate SSH or telnet access to neighboring switches when port isolation is turned on in the connected port.
CFD-11518 Operating system returns different PVID values when dynamic authentication is done on the port while polling for dot1qPvid OID.
CFD-11559 Configuration or the dos-protect detail output does not reflect when the management port is configured as a trusted-port.
CFD-11659 In certain platforms, including X435, X465, and 4120, L3 routed packets with dot1q header having CFI/DEI bit set to 1 are processed in the CPU.
CFD-11815 The ELRP process crashes when ELRP with Hardware Assist is enabled and is run on a VLAN that has more than 128 ports.
CFD-11913 Option to synchronize the files created in the primary slot to the backup is included in the synchronize command.
5320 Series Switches
CFD-11429 Policy disabled after a restart in 5320 series.
5520 Series Switches
CFD-11278 10070H optic port on 5520-48SE does not come up after reinserting and when the port speed is configured as 100Mbps.
7520 Series
CFD-11737 25G link does not come up after turning off/on Auto-neg settings in 7520.